Adding accommodation units to a campsite in Wallonia: planning permission, PEB, fire safety and electricity

Glazed Belvédère 27 capsule with its light strip on, on a pitch edged with forest

Since 1 July 2025, campsites in Wallonia are registered with Tourisme Wallonie rather than authorised, and a unit without wheels raises the question of planning permission. Here is what the Territorial Development Code (CoDT), the Walloon Tourism Code and the PEB decree say, and what to get in writing before you order.

What changed on 1 July 2025: registration and certification

Fixed or mobile shelter: where does a unit without wheels fit?

The Tourism Code calls the units on campsite pitches shelters (abris):

A rental unit that stays on its pitch for the whole season fits the definition of a fixed shelter.

Planning permission: why the exemption for mobile shelters may not cover your units

The CoDT requires planning permission (permis d'urbanisme) to build, or to use land to place fixed installations. That includes placing an installation, even of non-durable materials, whose support ensures its stability and which is meant to stay in place, even though it can be dismantled or moved (CoDT, article D.IV.4, 1°).

The regulatory part of the code exempts from permission, with no architect required, the placing of mobile shelters within the meaning of article 1 D, 2° of the Walloon Tourism Code, on cumulative conditions (table of article R.IV.1-1, heading V.1, in force since 1 July 2025):

The definition this heading refers to is that of the former Tourism Code, repealed on 1 July 2025: a structure designed to be easily dismantled or transportable (former article 1 D, 2°). Under that code, a mobile shelter on a campsite also kept its towbar and wheels, permanently and in working order (former article 249/3).

Our units have neither wheels nor a towbar, and they stay in place for the season: planning permission is likely. The municipal college (collège communal) decides on the application, depending on the case without an opinion, on the prior opinion or on the binding opinion of the delegated official (fonctionnaire délégué) (D.IV.14). An architect is not compulsory for placing one or more installations, fixed or mobile (R.IV.1-2, 3°).

How to get the municipality's position before you order

One unit per pitch, a third of the pitch, 4 m and 20 m: the certification rules

In a certified tourist campsite, the certification grid sets these conditions (Tourism Code, regulatory part, annex 3):

Smallest pitch for the one-third rule, without a deck
Unit and footprintSmallest pitch
Alcôve 14, 13.8 m²41.4 m²
Belvédère 27, 27.4 m²82.2 m²
Escale 36, 37.2 m² overall, expanded111.6 m²

Each square metre of deck adds 3 m² of pitch: with a 12 m² deck, an Escale 36 needs a pitch of at least 147.6 m².

Flood zones: where can units go?

In a certified tourist campsite, shelters, fixed or mobile, are allowed in the parts of the flood zone with a medium, low or very low hazard, with planning authorisation where the CoDT requires it. In the high-hazard zone, mobile homes, storage sheds, hedges, fences and similar installations are banned all year (R.III.31-3).

The operator can ask the appeals chamber (Chambre de recours) for a derogation, by showing that works carried out since the hazard map was drawn up reduce the hazard, or that the map contains a manifest error. The chamber is bound by unfavourable opinions from the Walloon public service and the burgomaster (R.III.31-4). The CoDT exemption for mobile shelters does not apply in a high flood-hazard zone either.

Check your pitches on the official flood hazard map (cartographie de l'aléa d'inondation) before choosing where the units go.

PEB: no energy requirements under 50 m²

The PEB requirements do not apply to buildings to be constructed with a total usable floor area under 50 m², and no PEB certificate is required below that size (PEB decree of 28 November 2013, articles 10, 5°, and 36, 3°). The usable floor area is measured between the outer walls, without their thickness (article 2, 12°): inside, the Escale 36 measures 35.2 m² with its 75 mm walls, and the capsules are smaller.

If your project needs planning permission, attach the PEB exception form to the application (Walloon PEB flowchart, June 2026).

Fire safety: a new certificate after adding units

The fire safety certificate (attestation de sécurité-incendie) is obtained for each building or part of a building, and a unit, a covered space surrounded by walls, fits the code's definition of a building. The burgomaster issues the certificate, which is valid for five years (D.I.1, 8°, and D.III.72 to D.III.74).

It lapses, and a new one must be obtained, in particular when new rooms for guests may increase the maximum capacity, when a gas or electricity network is installed, modified or extended, and for any transformation that needs planning permission. The previous certificate remains valid until the new application is decided, if you apply no later than 30 days after the end of the works (D.III.74).

What each unit for fewer than 10 people needs (annex 10)

Electricity: inspection by an approved body

In every tourist accommodation, the low-voltage installation is checked for conformity by a body approved by the minister responsible for energy: before it is put into use and whenever important modifications or extensions are made, then every five years. The report before putting into use must show no infringement (Tourism Code, annex 9, point 2.3).

Extending the campsite's network to new units also makes the fire safety certificate lapse (D.III.74). Our turnkey price includes the first inspection by an approved body.

Subsidies for certified tourist campsites

Within the budget available, the Region can subsidise works and equipment for the creation, extension and modernisation of tourist campsites (D.IV.82). The rate is 40%, which can be increased by up to 10% in some cases, with a ceiling of €80,000 per application and a project of at least €5,000; the aid falls under the EU de minimis rules (R.IV.86-2 to R.IV.86-4).

Before you order, note that:

We cannot tell you whether a unit bought from us qualifies: ask Tourisme Wallonie before you order.

Before you order: what to get in writing

  1. Your municipality's position on planning permission, through a project meeting or a planning certificate no. 2, before you sign the quote.
  2. Your registration and, if you want the name and the subsidies, your certification as a camping touristique.
  3. The size of your pitches (unit and deck on no more than a third), 4 m between units and 20 m from pre-existing neighbouring homes.
  4. The flood hazard of each pitch, on the official map.
  5. The new fire safety certificate: your application no later than 30 days after the works, with the certificate of conformity for the electrical installation.
  6. The notice to Tourisme Wallonie within 60 days of any change affecting your registration or certification.

A refused or delayed permit does not entitle you to cancel the order without compensation: that is why the municipality's position comes before you sign the quote. We supply the technical file for these steps: drawings, wiring diagram, list of components and the available reaction-to-fire classifications.

Our units and their turnkey prices in Belgium

Turnkey prices excluding VAT, for a standard pitch: the unit delivered to your pitch, customs duty, installation and connections by the partner installer named in your quote, inspection of the electrical installation by an approved body and commissioning. The exact price is confirmed in your written quote.

Frequently asked questions

Do I need planning permission for a capsule on a Walloon campsite?

Probably. The CoDT exemption covers mobile shelters as defined by the former Tourism Code, under which they kept their wheels and towbar. A unit without wheels that stays in place for the season is an installation meant to stay in place. Ask your municipality before you order.

Is an architect compulsory?

No, not for placing one or more installations, fixed or mobile (CoDT, article R.IV.1-2, 3°).

Does adding units affect my fire safety certificate?

Yes. New rooms for guests that may increase capacity, an extension of the electricity network or works that need planning permission make the certificate lapse. Apply for a new one no later than 30 days after the end of the works.

Do the PEB rules apply to a unit of 37 m²?

No. Buildings to be constructed with a total usable floor area under 50 m² are outside the PEB requirements and need no PEB certificate. With a permit application, attach the exception form.

Can I place units in the flood zone of my campsite?

In a certified tourist campsite, yes in the medium, low or very low hazard parts, with planning authorisation where required. Not in the high-hazard zone, unless the appeals chamber grants a derogation.

Must my campsite be certified?

Registration is compulsory; certification is optional. Only a certified campsite may use the name camping touristique and apply for the Tourism Code subsidies, and the certification rules (a third of the pitch, 4 m, 20 m) apply to it.

Is your campsite in Flanders? The rules there are different: see our guide to placing a chalet, capsule or expandable container house on a Flemish campsite.

General information, based on official sources read on 26 October 2026 (Wallex, energie.wallonie.be). It does not replace the position of your municipality, Tourisme Wallonie or your emergency zone, or advice from a lawyer. Rules change: check the current version before you commit.